Advanced Materials Research (Volumes 317 - 319), Pages 66-69 (2011)
Yong Zhang Zhou, Min Liu, Xin Ni, Dong Sheng Chen, Wu Ji Wei
Abstract
Hysteretic loops were used to study the influence of several ions in sedimentary water of oil tank on local corrosion at the bottom of crude oil tank. They were measured by the electrochemical station CHI660.
The most serious pitting corrosion occurred under the following condition: the concentration of Cl-, SO42-, HCO3-, Mg2+, Ca2+ were 10.0 g/L, 1.0 g/L, 0.75 g/L, 0.35 g/L, 0.2 g/L, respectively.
Full Text Source (Subscription or Fee): http://www.scientific.net/AMR.317-319.66