CATEGORY: FUEL CELLS
Applied Energy, Volume 103, March 2013, Pages
607–617
Incorporating
available micro gas turbines and fuel cell: Matching considerations and
performance evaluation
Diamantis P. Bakalis, Anastassios G. Stamatis
University of Thessaly, Department of Mechanical Engineering, Leoforos Athinon,
Pedion Areos, 38334 Volos, Greece
Abstract
Provides
results of a study of the performance of the hybrid systems based on the fuel
cell stack developed by Siemens-Westinghouse coupled with four different
commercially available recuperated micro-turbines.
Researchers studied the by developing appropriate simulation models
validated with available data. Full and part load performance of those systems
are presented and discussed. Study results revealed that the smaller the
micro-turbine coupled with the Siemens-Westinghouse SOFC generator, the more
efficient the corresponding hybrid system. Researchers also observed that when
the power requirements are low, the designer may choose a larger micro-turbine
than the required, as the system operates efficiently also at higher loads than
the base and could satisfy peak energy demands.
Full Text Source (Subscription or Fee): http://www.sciencedirect.com/science/article/pii/S0306261912007325