Monday, April 2, 2012

Long Term Operating Experience with Corrosion Control in Industrial Axial Flow Compressors

Proceedings of the Fortieth Turbomachinery Symposium,  September 12-15, 2011, Houston, Texas
Long Term Operating Experience with Corrosion Control in Industrial Axial Flow Compressors
David Linden, President
D.H.Linden Associates, Inc., Allentown, PA, USA
ABSTRACT
A primary cause of flow path failures in industrial axial flow compressors is related to corrosion damage. Various corrosion mitigations have been employed by manufacturers and users. Authors summarize several long term monitoring and assessment programs designed to evaluate the effectiveness of the mitigation steps.  They then make recommendations for future operation.
The monitoring programs included detailed metallurgical analyses of corroded stator and rotor blades, material captured in inlet filter pads, flow path deposits and corrosion coupons. The hardware was examined at various run time intervals that ranged between 2 to 12 years. When possible, corrosion damage was mapped and quantified. The hardware was then returned to service and later re-evaluated in the exact same locations after the additional operating time.
Free Full Text Source: http://turbolab.tamu.edu/uploads/tproc/PDFs/LongTermOPeratingExperience.pdf